SeriesEquipmentDependentLimit

Limit based on most restrictive equipment limit. A specification of equipment that determines the calculated operational limit values based upon other equipment and their ratings. The most restrictive limit connected within the group is used. The physical connection based on switch status for example may also impact which elements in the group are considered. Any equipment in the group that are presently connected with the equipment of the directly associated operational limit are used. This provides a means to indicate which potentially equipment limits are considered for a computed operational limit. The operational limit of the same operational limit type is assumed to be used from the grouped equipment. It is also possible to make assumptions or calculations regarding how flow might split if the equipment is not simply in series.

Type

Class

URI

cim:SeriesEquipmentDependentLimit

CIM standard (perspective)

IEC61970 (Grid)

Class hierarchy

Slots

Associated classes
Figure 1. Associated classes
Name Type Description Inherited from

EquipmentLimitSeriesComponent

0..*
EquipmentLimitSeriesComponent

Equipment linkages that participates in the limit calculation.

n/a

OperationalLimit

0..*
OperationalLimit

The operational limits to which this limit dependency model applies.

LimitDependency

description

0..1
string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to...

IdentifiedObject

europeanArticleNumberEAN

0..1
string

The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters...

IdentifiedObject

mRID

1
string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is...

IdentifiedObject

name

0..1
string

The name is any free human readable and possibly non unique text naming the object.

IdentifiedObject


description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

URI

cim:IdentifiedObject.description

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

EquipmentLimitSeriesComponent

Equipment linkages that participates in the limit calculation.

URI

cim:SeriesEquipmentDependentLimit.EquipmentLimitSeriesComponent

Cardinality

0..*

Type

EquipmentLimitSeriesComponent

europeanArticleNumberEAN

The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters as defined by the EAN code.

URI

nl:IdentifiedObject.europeanArticleNumberEAN

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

mRID

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

URI

cim:IdentifiedObject.mRID

Cardinality

1

Type

string

Inherited from

IdentifiedObject

name

The name is any free human readable and possibly non unique text naming the object.

URI

cim:IdentifiedObject.name

Cardinality

0..1

Type

string

Inherited from

IdentifiedObject

Glossary mappings

has exact match
  • ck:EnergyArea.short_code

OperationalLimit

The operational limits to which this limit dependency model applies.

URI

cim:LimitDependency.OperationalLimit

Cardinality

0..*

Type

OperationalLimit

Inherited from

LimitDependency