Switch
A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only .normalOpen is relevant.
Type |
Class |
|---|---|
URI |
|
CIM standard (perspective) |
IEC61970 (Grid) |
Slots
| Name | Type | Description | Inherited from |
|---|---|---|---|
0..1 |
The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement... |
n/a |
|
0..1 |
Container of this equipment. |
||
0..1 |
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases... |
||
0..* |
Reporting groups to which this power system resource belongs. |
||
0..1 |
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to... |
||
0..1 |
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters... |
||
1 |
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is... |
||
0..1 |
The name is any free human readable and possibly non unique text naming the object. |
aggregate
The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
description
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
EquipmentContainer
Container of this equipment.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
europeanArticleNumberEAN
The attribute is used for an exchange of the EAN code (European Article Number). The length of the string is 18 characters as defined by the EAN code.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
mRID
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
URI |
|
|---|---|
Cardinality |
1 |
Type |
|
Inherited from |
name
The name is any free human readable and possibly non unique text naming the object.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |
|
Inherited from |
|
Glossary mappings |
|
normalOpen
The attribute is used in cases when no Measurement for the status value is present. If the Switch has a status measurement the Discrete.normalValue is expected to match with the Switch.normalOpen.
URI |
|
|---|---|
Cardinality |
0..1 |
Type |